Share

Snyder

Summary of Drinking Water Samples Tested by the Penn State Agricultural Analytical Services Laboratory

Snyder County

1/18/2007 - 4/1/2016, 72 Samples

Test Parameter Units Number of Samples Tested Median Minimum Maximum Number of samples failing EPA Std Percent of samples failing EPA Std EPA Drink Water Std
Total
Coliform
MPN/100
mL
67 0.0 0.0 200.5 33 49.3 0
E.
Coli
MPN/100
mL
67 0.0 0.0 165.2 6 9.0 0
pH
-
63 7.7 6.0 10.0 8 12.7 6.5-8.5
Total
Dissolved
Solids
mg/L 63 179.0 27.0 623.0 2 3.2 500
Corrosivity
Index*

-
21 -0.1 -2.0 0.9 10 47.6 -
Hardness mg/L 21 74.1 0.8 284.5 - - -
Nitrate+Nitrite
N
mg/L 17 0.5 0.2 12.3 1 5.9 10
Chloride mg/L 1 5.0 5.0 5.0 0 0.0 250
Sulfate mg/L 2 11.7 10.0 13.4 0 0.0 250
Aluminum mg/L 0 - - - - - 0.05-0.2
Arsenic mg/L 1 0.00 0.003 0.003 0 0.0 0.01
Barium mg/L 1 0.12 0.12 0.12 0 0.0 2
Cadmium mg/L 1 0.00 0.001 0.001 0 0.0 0.005
Calcium mg/L 21 18.02 0.25 104.85 - - -
Chromium mg/L 1 0.0 0.005 0.005 0 0.0 0.1
Copper mg/L 23 0.01 0.01 0.30 0 0.0 1.0,1.3
Iron mg/L 22 0.1 0.1 4.2 3 13.6 0.3
Lead-1st
draw
mg/L 7 0.00 0.003 0.005 0 0.0 0.015
Lead-Running mg/L 7 0.003 0.003 0.018 1 14.3 0.015
Magnesium mg/L 21 5.78 0.05 15.03 - - -
Manganese mg/L 22 0.01 0.01 0.31 8 36.4 0.05
Mercury mg/L 1 0.00 0.001 0.001 0 0.0 0.002
Nickel mg/L 1 0.01 0.005 0.005 - - -
Sodium mg/L 0 - - - - - -
Zinc mg/L 1 0.01 0.01 0.01 0 0.0 5

*For corrosivity index, failure criteria based on less than -0.5 or greater than 0.5