Share

Wayne

Summary of Drinking Water Samples Tested by the Penn State Agricultural Analytical Services Laboratory

Wayne County

9/11/2007 - 6/18/2018, 382 Samples

Test Parameter Units Number of Samples Tested Median Minimum Maximum Number of samples failing EPA Std Percent of samples failing EPA Std EPA Drink Water Std
Total
Coliform
MPN/100
mL
363 0.0 0.0 200.5 111 30.6 0
E.
Coli
MPN/100
mL
363 0.0 0.0 200.5 27 7.4 0
pH
-
349 7.6 5.9 10.0 30 8.6 6.5-8.5
Total
Dissolved
Solids
mg/L 342 124.0 20.0 1012.0 4 1.2 500
Corrosivity
Index*

-
104 -0.6 -3.5 1.8 58 55.8 -
Hardness mg/L 138 74.0 0.8 174.7 - - -
Nitrate+Nitrite
N
mg/L 74 0.5 0.2 5.9 0 0.0 10
Chloride mg/L 130 3.5 1.0 114.7 0 0.0 250
Sulfate mg/L 17 8.4 5.5 14.2 0 0.0 250
Aluminum mg/L 10 0.0 0.0 0.1 0 0.0 0.05-0.2
Arsenic mg/L 87 0.00 0.001 0.035 11 12.6 0.01
Barium mg/L 161 0.08 0.01 1.41 0 0.0 2
Cadmium mg/L 40 0.00 0.001 0.028 1 2.5 0.005
Calcium mg/L 128 24.47 0.25 60.48 - - -
Chromium mg/L 40 0.0 0.001 0.006 0 0.0 0.1
Copper mg/L 132 0.03 0.01 6.08 1 0.8 1.0,1.3
Iron mg/L 148 0.2 0.0 4.2 14 9.5 0.3
Lead-1st
draw
mg/L 51 0.01 0.003 0.059 8 15.7 0.015
Lead-Running mg/L 108 0.004 0.003 0.716 1 0.9 0.015
Magnesium mg/L 111 2.86 0.05 20.72 - - -
Manganese mg/L 142 0.01 0.01 11.17 34 23.9 0.05
Mercury mg/L 55 0.00 0.000 28.365 19 34.5 0.002
Nickel mg/L 33 0.01 0.005 0.010 - - -
Sodium mg/L 49 4.00 0.01 77.34 - - -
Zinc mg/L 52 0.01 0.00 0.53 0 0.0 5

*For corrosivity index, failure criteria based on less than -0.5 or greater than 0.5