Summary of Drinking Water Samples Tested by the Penn State Agricultural Analytical Services Laboratory

Washington County

10/30/2007 - 7/18/2024, 406 Samples

Test Parameter Units Number of Samples Tested Median Minimum Maximum Number of samples failing EPA Std Percent of samples failing EPA Std EPA Drink Water Std
Total
Coliform
MPN/100
mL
386 23.0 0.0 1011.2 265 68.7 0
E.
Coli
MPN/100
mL
386 0.0 0.0 200.5 111 28.8 0
pH
-
339 7.6 5.9 9.2 18 5.3 6.5-8.5
Total
Dissolved
Solids
mg/L 338 349.0 20.0 1546.0 61 18.0 500
Corrosivity
Index*

-
105 0.5 -2.3 1.1 75 71.4 -
Hardness mg/L 114 238.7 0.8 785.4 - - -
Nitrate+Nitrite
N
mg/L 94 0.5 0.2 6.2 0 0.0 10
Chloride mg/L 149 15.6 1.1 564.8 6 4.0 250
Sulfate mg/L 44 33.8 1.0 226.4 0 0.0 250
Aluminum mg/L 34 0.0 0.0 4.1 6 17.6 0.05-0.2
Arsenic mg/L 100 0.00 0.001 0.011 1 1.0 0.01
Barium mg/L 191 0.09 0.00 2.34 1 0.5 2
Cadmium mg/L 54 0.00 0.001 0.002 0 0.0 0.005
Calcium mg/L 103 68.75 0.25 246.01 - - -
Chromium mg/L 54 0.0 0.001 0.005 0 0.0 0.1
Copper mg/L 160 0.01 0.01 1.04 0 0.0 1.0,1.3
Iron mg/L 108 0.1 0.1 19.9 16 14.8 0.3
Lead-1st
draw
mg/L 85 0.00 0.003 0.021 2 2.4 0.015
Lead-Running mg/L 113 0.003 0.003 1.114 7 6.2 0.015
Magnesium mg/L 103 15.37 0.05 65.68 - - -
Manganese mg/L 126 0.01 0.01 4.61 18 14.3 0.05
Mercury mg/L 50 0.00 0.000 0.001 0 0.0 0.002
Nickel mg/L 54 0.01 0.005 0.022 - - -
Sodium mg/L 20 37.59 0.25 159.30 - - -
Zinc mg/L 54 0.01 0.005 0.22 0 0.0 5

*For corrosivity index, failure criteria based on less than -0.5 or greater than 0.5