Test Parameter Units Number of Samples Tested Median Minimum Maximum Number of samples failing EPA Std Percent of samples failing EPA Std EPA Drink Water Std
Total
Coliform
MPN/100
mL
287 0.0 0.0 200.5 126 43.9 0
E.
Coli
MPN/100
mL
287 0.0 0.0 200.5 35 12.2 0
pH
-
165 7.4 5.3 9.4 35 21.2 6.5-8.5
Total
Dissolved
Solids
mg/L 164 130.0 20.0 2135.0 3 1.8 500
Corrosivity
Index*

-
86 -1.1 -4.7 1.1 59 68.6 -
Hardness mg/L 96 51.5 0.8 399.2 - - -
Nitrate+Nitrite
N
mg/L 108 0.5 0.2 12.5 2 1.9 10
Chloride mg/L 49 5.0 1.0 58.5 0 0.0 250
Sulfate mg/L 22 10.0 1.0 40.2 0 0.0 250
Aluminum mg/L 12 0.0 0.0 0.1 2 16.7 0.05-0.2
Arsenic mg/L 79 0.00 0.001 0.062 11 13.9 0.01
Barium mg/L 90 0.04 0.00 5.77 1 1.1 2
Cadmium mg/L 4 0.00 0.001 0.002 0 0.0 0.005
Calcium mg/L 93 14.72 0.25 119.33 - - -
Chromium mg/L 4 0.0 0.001 0.005 0 0.0 0.1
Copper mg/L 94 0.01 0.01 3.45 1 1.1 1.0,1.3
Iron mg/L 58 0.1 0.1 93.0 10 17.2 0.3
Lead-1st
draw
mg/L 67 0.00 0.003 0.027 1 1.5 0.015
Lead-Running mg/L 86 0.003 0.003 0.010 0 0.0 0.015
Magnesium mg/L 93 3.08 0.05 24.58 - - -
Manganese mg/L 59 0.01 0.01 7.46 15 25.4 0.05
Mercury mg/L 4 0.00 0.000 0.001 0 0.0 0.002
Nickel mg/L 4 0.01 0.005 0.010 - - -
Sodium mg/L 15 11.32 1.43 56.78 - - -
Zinc mg/L 4 0.01 0.006 0.01 0 0.0 5

*For corrosivity index, failure criteria based on less than -0.5 or greater than 0.5