Test Parameter Units Number of Samples Tested Median Minimum Maximum Number of samples failing EPA Std Percent of samples failing EPA Std EPA Drink Water Std
Total
Coliform
MPN/100
mL
321 0.0 0.0 378.0 130 40.5 0
E.
Coli
MPN/100
mL
321 0.0 0.0 200.5 21 6.5 0
pH
-
262 7.3 4.9 8.4 38 14.5 6.5-8.5
Total
Dissolved
Solids
mg/L 261 198.0 10.0 1508.0 12 4.6 500
Corrosivity
Index*

-
147 -1.1 -4.8 0.6 102 69.4 -
Hardness mg/L 157 87.5 0.8 933.1 - - -
Nitrate+Nitrite
N
mg/L 144 2.9 0.2 11.3 4 2.8 10
Chloride mg/L 21 11.8 1.4 210.6 0 0.0 250
Sulfate mg/L 33 10.5 1.0 55.1 0 0.0 250
Aluminum mg/L 7 0.0 0.0 0.1 2 28.6 0.05-0.2
Arsenic mg/L 90 0.00 0.001 0.027 6 6.7 0.01
Barium mg/L 40 0.06 0.00 0.61 0 0.0 2
Cadmium mg/L 15 0.00 0.001 0.002 0 0.0 0.005
Calcium mg/L 146 23.86 0.25 334.43 - - -
Chromium mg/L 15 0.0 0.001 0.005 0 0.0 0.1
Copper mg/L 165 0.02 0.01 3.41 2 1.2 1.0,1.3
Iron mg/L 150 0.1 0.1 11.4 24 16.0 0.3
Lead-1st
draw
mg/L 138 0.00 0.003 0.057 14 10.1 0.015
Lead-Running mg/L 116 0.003 0.003 0.025 1 0.9 0.015
Magnesium mg/L 146 6.56 0.05 40.93 - - -
Manganese mg/L 153 0.01 0.01 2.61 30 19.6 0.05
Mercury mg/L 17 0.00 0.000 0.001 0 0.0 0.002
Nickel mg/L 15 0.01 0.005 0.077 - - -
Sodium mg/L 42 14.97 2.95 229.84 - - -
Zinc mg/L 15 0.01 0.005 1.59 0 0.0 5

*For corrosivity index, failure criteria based on less than -0.5 or greater than 0.5