Test Parameter Units Number of Samples Tested Median Minimum Maximum Number of samples failing EPA Std Percent of samples failing EPA Std EPA Drink Water Std
Total
Coliform
MPN/100
mL
293 1.0 0.0 200.5 147 50.2 0
E.
Coli
MPN/100
mL
293 0.0 0.0 200.5 26 8.9 0
pH
-
275 6.7 4.7 9.8 106 38.5 6.5-8.5
Total
Dissolved
Solids
mg/L 275 136.0 20.0 645.0 2 0.7 500
Corrosivity
Index*

-
104 -1.7 -4.2 0.8 79 76.0 -
Hardness mg/L 110 70.7 0.8 364.2 - - -
Nitrate+Nitrite
N
mg/L 146 4.8 0.2 33.1 13 8.9 10
Chloride mg/L 9 7.5 5.0 36.6 0 0.0 250
Sulfate mg/L 10 11.2 5.7 30.5 0 0.0 250
Aluminum mg/L 9 0.0 0.0 0.1 1 11.1 0.05-0.2
Arsenic mg/L 61 0.00 0.001 0.008 0 0.0 0.01
Barium mg/L 27 0.04 0.00 0.60 0 0.0 2
Cadmium mg/L 17 0.00 0.001 0.002 0 0.0 0.005
Calcium mg/L 105 13.82 0.25 82.23 - - -
Chromium mg/L 17 0.0 0.001 0.005 0 0.0 0.1
Copper mg/L 120 0.04 0.01 4.36 5 4.2 1.0,1.3
Iron mg/L 109 0.1 0.0 25.0 9 8.3 0.3
Lead-1st
draw
mg/L 49 0.01 0.003 0.095 15 30.6 0.015
Lead-Running mg/L 96 0.003 0.003 0.500 9 9.4 0.015
Magnesium mg/L 92 5.49 0.05 45.59 - - -
Manganese mg/L 107 0.01 0.01 13.34 33 30.8 0.05
Mercury mg/L 33 0.00 0.000 0.278 13 39.4 0.002
Nickel mg/L 15 0.01 0.005 0.022 - - -
Sodium mg/L 13 0.01 0.01 0.25 - - -
Zinc mg/L 25 0.01 0.00 0.38 0 0.0 5

*For corrosivity index, failure criteria based on less than -0.5 or greater than 0.5